  200 watts pm200 series 4000 vac isolation 100% burn-in low safety leakage current short circuit protection meets emi requirements of medical equipment both line and neutral fused for european requirements specification all specifications typical at nominal line, full load and 25? i ntelligent design q uality product xpiq inc. medical switching power supply input input voltage 90 to 130 vac or 180 to 264 vac autoranging input frequency 47 to 440 hz input current 4.5a (rms) for 115 vac 2.6a (rms) for 230 vac safety ground 50? max. at 110 vac 60 hz leakage current 100? max. at 240 vac 50 hz output total output power: 15 to 200 watts ripple and noise: 2% peak to peak maximum overvoltage provided on output #1 only; protection: set at 112-132% of its nominal output voltage overcurrent all outputs protected to short protection: circuit conditions temperature all outputs ?.04%/? coefficient: maximum transient response: maximum excursion of 4% or better on all models, recovering to 1% of final value 500us after a 25% step load change line regulation ?.5% max. at full load general efficiency 70% minimum at 200 watt output hold-up time 20 msec minimum at nominal input inrush current 60a max at 25? cold start withstand voltage 4000 vac from input to output 1500 vac from input to ground 500 vac from output to ground environmental operating 0? to +70?* temperature storage -40? to +85? temperature relative humidity 5% to 95% non-condensing mtbf 85,000 hours minimum at full load at 25? ambient emi requirement meets the conducted limits of en 55011 (cispr11) level b safety requirements approved to: (not for patient contact) a) ul2601 b) csa c22.2 no.601.1-m90 per cul c) iec 601-1/en60601-1 (per tuv) * derate linearly from 100% load at 50? to 50% load at 70? ph: 508 429.9883 fax: 800 226.2100 email: sales@xp-iq.com holliston, ma 01746 usa www. xp- i q .com 157 145-166 1/5/02 11:12 am page 13
connectors p1 p2 p3 model 1 2 3 1, 2 3, 4, 5 6 7 8 9 1 2 3 4 pm200-10 pm200-12 ac ac ac output output output common common pm200-13 pm200-14 line neutral ground -sense return #i #i #1 +sense pfd return return fan pm200-16 pm200-18 pm200-23 pm200-24 ac ac ac output common output n.c. n.c. n.c. pfd common common fan pm200-25 line neutral ground #1 return #2 return return pm200-30 pm200-31 ac ac ac output common output output n.c. n.c. pfd common common fan pm200-32 line neutral ground #1 return #2 #3 return return pm200-40 pm200-41 ac ac ac output common output output output output common common pm200-42 line neutral ground #1 return #2 #3 #4 #4 pfd return return fan pm200-45 return output voltage & current ratings pm200 notes mechanical details pin chart notes: 1. dimensions shown in inches (mm) 2. tolerance 0.02 (0.5) maximum) 3. input connector p1 is beau inc. p/n 72-5-03c. output connector p2 is beau inc. p/n 72-5-09c. screws are #6-32 on 0.375 inch centers. 4. connector p3 mates with molex housing 22-01-1043 and molex 40445 series crimp terminal 5. weight: 1.4 kgs (3.10 lbs) approx. for ??version 1.75 kgs (3.90 lbs) approx. for ??version output #1 output #2 output #3 output #4 maximum output model vnom imin imax tol. vnom imin imax tol. vnom imin imax tol. vnom imin imax tol. power 2 pm200-10 5 v 3.0 a 40.0 a 2% 200 w pm200-12 12 v 1.2 a 16.7 a 2% 200 w pm200-13 15 v 1.0 a 13.0 a 2% 200 w pm200-14 24 v 0.6 a 8.4 a 2% 200 w pm200-16 30 v 0.5 a 6.7 a 2% 200 w pm200-18 48 v 0.3 a 4.2 a 2% 200 w pm200-23 +5 v 3.0 a 30.0 a 2% +12 v 0 a 8 a 4% 200 w pm200-24 +5 v 3.0 a 30.0 a 2% +15 v 0 a 6 a 4% 200 w pm200-25 +5 v 3.0 a 30.0 a 2% +24 v 0 a 4 a 4% 200 w pm200-30 +5 v 3.0 a 30.0 a 2% +12 v 0 a 8 a 4% -5 v 0 a 6 a 4% 200 w pm200-31 +5 v 3.0 a 30.0 a 2% +12 v 0 a 8 a 4% -12 v 0 a 4 a 4% 200 w pm200-32 +5 v 3.0 a 30.0 a 2% +15 v 0 a 6 a 4% -15 v 0 a 4 a 4% 200 w pm200-40 +5 v 3.0 a 30.0 a 2% +12 v 0 a 8 a 4% -12 v 0 a 4 a 4% f 5 v 0 a 6 a 4% 200 w pm200-41 +5 v 3.0 a 30.0 a 2% +15 v 0 a 6 a 4% -15 v 0 a 4 a 4% f 24 v 0 a 4 a 4% 200 w pm200-42 +5 v 3.0 a 30.0 a 2% +12 v 0 a 8 a 4% -12 v 0 a 4 a 4% f 12 v 0 a 4 a 4% 200 w pm200-45 +5 v 3.0 a 30.0 a 2% +12 v 0 a 8 a 4% -12 v 0 a 4 a 4% f 24 v 0 a 4 a 4% 200 w 1. add suffix "b" for u-bracket or "c" for enclosed form e.g. pm200-45c. 2. peak current is 12a on +12v, 9a on +15 v, and 6a on +24v. 3. output #4 is floating. it can be connected externally for positive or negative output. 4. 200 watts for "c" version with a cover-and-fan assembly. 150 watts for "b" version without moving air. (max current of output #1 & #2 derated to 70%) or 200 watts (no derating) with 25 cfm forced air provided by user. ph: 508 429.9883 fax: 800 226.2100 email: sales@xp-iq.com holliston, ma 01746 usa www. xp- i q .com 158 145-166 1/5/02 11:12 am page 14


▲Up To Search▲   

 
Price & Availability of PM200-14B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X